View our Products by specific category below:
|
| Home > Products > Burners > Pre-Mix Burners |
| Ribbon Burner Selection Data |
|
|
Selas Ribbon Burners - How To Specify A Catalog Number.
(Data selection tables are listed at bottom of page)
- Specify Series Number (Schedule 1), based on burner requirements as to flame width, length and heat capacity, etc.
- As prefix to Series Number, indicate special feature type (A, B, C, etc.) from Schedule 2.
- As suffix to Series Number, list flame length (Schedule 1).
- Example: A series 822B Ribbon Burner, with end inlet and electric ignition (Special Feature Type E) and 48 in. flame length-has the following catalog number (RB indicates Ribbon Burner): RB E 822B 48 OR RB-E-822B-48
Notes:
- Standard flame lengths are in increments of 6 in.
- Maximum and minimum flame lengths are listed in Schedule 1.
- Flame stops are supplied in increments of 3 in., up to 50% of flame length.
- End-inlet burners can have only one flame stop; bottom-inlet burners can employ one or two.
- Bottom-inlet burners, with flame length up to 24 in., have inlet in center; bottom-inlet burners, with flame length over 24 in., have inlet 12 in. from one end of flame.
|
| View Schedule 1, Schedule 2, End & Bottom Inlet Combinations |
| Home > Products > Burners > Pre-Mix Burners |
|
|